MHC Medical Products Easy-Touch Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Pomiary, testowanie i kontrola MHC Medical Products Easy-Touch. MHC Medical Products Easy-Touch User manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Easy•Touch

Easy•Touch®Glucose Monitoring SystemUser Manual

Strona 2

8The EasyTouch® Glucose Meter & Monitoring System is available in two different package options with the following contents:A. Your EasyTouch® Glu

Strona 3 - Table of Contents

9About the EasyTouch® MeterS/N:M05B13286BLOOD GLUCOSE METEREasy•Touch®For In Vitro Diagnostic Use OnlyMade in Taiwan to Specs of MHC Medical Products,

Strona 4

101. Display Your test results are displayed here. The large, easy to read screen guides you through the test by using numbers and symbols. 2

Strona 5 - Important Information

111. Date2. Time3. Control Solution TestAppears when doing a control solution test and marking the result as a control solution test.4. Memory Symb

Strona 6

126. Battery Symbol Appears when the battery is low or must be replaced.7. Blood Drop Symbol Flashes when it is ready to apply sample to Tes

Strona 7

13About the EasyTouch® Test StripThe EasyTouch® Test Strip is used to perform the blood glucose test in conjunction with the EasyTouch® Meter.Each st

Strona 8

14WARNING: Re-cap immediately & always close lid tightly.Store at 39-86°F (4-30°C). Do not refrigerate. Always store test strips inside vial.Disca

Strona 9 - Introduction

15When the battery is low, the Meter will show a warning signal. When this display appears, it is time to replace a new battery. When the low battery

Strona 10 - About the Product

16Setting Up the MeterSetting Up the Date & TimeTo turn the Meter on, rst insert a battery, then press the reset button located at the back of th

Strona 11 - About the EasyTouch

174. To set the day and move on to choose the hour setting, press the M button. (Fig.3) 5. To change the hour, press the S button. To set the hour and

Strona 12

See our other products at www.EasyTouchProducts.comEasy•Touch®Glucose Monitoring System

Strona 13 - Meter Display

188. To set the second alarm, press the M button (yes). If you press S button (no), it will be moved on to health management alarm setting (step 11)

Strona 14

1910. To set the fourth alarm, press the M button (yes). If you press S button (no), it will be moved on to health management alarm setting (step 11).

Strona 15 - Test Strip

20S/N:M05B13286BLOOD GLUCOSE METEREasy•Touch®For In Vitro Diagnostic Use OnlyMHC Medical Products, LLC.8695 Seward RoadFaireld, OH 45011Toll #: 877.3

Strona 16 - 50 TEST STRIPS

21When to Perform a Control Solution TestEasy•Touch® Control Solution can be used to verify that the Easy•Touch® Glucose Monitoring system is working

Strona 17

22To Perform a Control Solution Test1. Make sure the Control Solution is at room temperature (59ºF to 95ºF or 15ºC to 35ºC) prior to testing. 2. Inser

Strona 18 - Setting Up the Meter

235. Discard the rst drop of Control Solution and squeeze a small drop of Control Solution on a clean nonabsorbent surface (such as a clean piece of

Strona 19

24Comparing Control Solution ResultsThe EasyTouch® Glucose Monitoring System is functioning properly if the results fall inside the specied range pri

Strona 20

25Testing Your Blood Glucose LevelBefore testing blood glucose, you need the following items:1. EasyTouch® Meter 2. EasyTouch® Test Strip 3. Adjustab

Strona 21

26Preparing the Test Strip1. Wash hands using soap and warm water. Rinse and dry thoroughly.2. Pull out a Test Strip from the vial and re-cap the vial

Strona 22 - Unit Selection

27Obtaining a Blood SampleSAMPLE MAY BE OBTAINED FROM FINGER, PALM or FOREARMFor further instructions please see the insert provided with lancing devi

Strona 23

Important Information ...3Introduction ...

Strona 24

28Applying Blood Sample to the EasyTouch® Test Strip1. After obtaining a blood sample, place the drop onto the test well of the Test Strip. Blood is a

Strona 25

293. After the test result appears, if no further tests are performed, the Meter will automatically shut off after 3 minutes. After nishing the test,

Strona 26

30HI and LO Readings1. The test results range between 20 to 600 mg/dL (1.1 to 33.3 mmol/L). If a “HI” message appears on the display, your Meter has d

Strona 27

31Memory FeaturesThe EasyTouch® Meter automatically stores the 300 most recent blood glucose results with date and time in its memory. It also provide

Strona 28 - Preparing the Test Strip

32Exiting the Memory Mode1. Press the M button to turn off the meter.2. Meter will shut down automatically after 3 minutes with no further action.Note

Strona 29 - Obtaining a Blood Sample

33Transfer Test Results to a ComputerWith the EasyTouch® Glucose Monitoring System, it is easy to transfer test results to your personal computer. Fo

Strona 30

34For healthcare professionals using this system on multiple patient, please be aware that all items that come in contact with human blood should be h

Strona 31

35DISPLAY WHAT IT MEANS ACTIONDisplay MessagesSystem check for verifying that all segments of the meter are functioning.No action necessaryThe system

Strona 32 - HI and LO Readings

36DISPLAY WHAT IT MEANS ACTIONIndicate the result is HIGHER than the “HI alarm setting” of the health management.For your reference or you can change

Strona 33 - Memory Features

37DISPLAY WHAT IT MEANS ACTIONMeter detects blood glucose level is lower than 20 mg/dL (1.1 mmol/L).Indicates low blood glucose level. Repeat test. If

Strona 34 - To Record Your Results

The Control Solution Test ... 21 Testing Your Blood Glucose Level ...

Strona 35

38DISPLAY WHAT IT MEANS ACTIONTemperature is too high to perform the test.Repeat the test in a cooler setting (10 - 40°C or 50 - 104°F). Wait 15 minut

Strona 36 - Care and Storage

39DISPLAY WHAT IT MEANS ACTIONAn error message indicating a problem with the meter.Press “reset” button and check the meter again with the test strip.

Strona 37 - Display Messages

40DISPLAY WHAT IT MEANS ACTIONAll testing values recorded in the memory have been shown.The setting alarm is ringing to remind of doing the blood gluc

Strona 38

41Other problems that may occurActionThe Test Strip has not been inserted into the meter properly.Review the instructions and re-insert the Test Strip

Strona 39

42Meter Operating ConditionsTemperature 10°C - 40°C(50°F - 104°F)Humidity 10-90% RHHematocrit 35 - 55%Test Sample Cap

Strona 40

43Limitations of the ProcedureCaution: The EasyTouch® Glucose Monitoring System is designed for in vitro diagnostic use only and is not intended to t

Strona 41

44Service and WarrantyMHC Medical Products, LLC cannot endorse the performance of the EasyTouch® Meter when used with Test Strips other than those des

Strona 42

45TRUE Lifetime WarrantyMHC Medical Products, LLC guarantees that this device will be free of defects in materials and workmanship for lifetime durati

Strona 43

46Customer ServiceIf you have any questions or concerns regarding this product or its operation, please call our Customer Service line or email us. W

Strona 44 - Specications

Toll: 1.877.358.4342Web: www.EasyTouchProducts.comEmail: [email protected] Seward Road, Faireld, Ohio 45011®

Strona 45 - Limitations of the Procedure

3There are limitations for doing AST. Please consult your healthcare professional before you do AST.ForearmPalmAvailable Alternate Sites Testing : Pal

Strona 46 - Service and Warranty

4Alternative site results differ from ngertip results when glucose levels are changing rapidly such as after a meal, after taking insulin, during exe

Strona 47 - TRUE Lifetime Warranty

52. Talk to your doctor to see if alternate site testing is right for you. With a little bit of education, you can give your ngertips a rest and mayb

Strona 48 - DH-080411.10

6• Low or high blood glucose readings can indicate a potentially serious medical condition. If your blood glucose reading is unusually low or high, o

Strona 49 - Toll: 1.877.358.4342

7Thank you for choosing the EasyTouch® Glucose Monitoring System, the latest advancement in biosensor technology. Recognized for its ease of use and q